LabToolsThe Research Infrastructure
  • Features
  • Demo
  • Technology
  • Examples
  • Plans
  • White Paper
  • Data Analysis ↗
  • Calculators
  • Scheduler

Choose a language

  • English
  • 简体中文
  • Español
  • Français
  • Deutsch
  • Português (Brasil)
  • 日本語
  • हिन्दी
  • বাংলা
  • தமிழ்
  • తెలుగు
  • मराठी
Download
FeaturesDemoTechnologyExamplesPlansWhite PaperData Analysis ↗CalculatorsScheduler

Language

  • English
  • 简体中文
  • Español
  • Français
  • Deutsch
  • Português (Brasil)
  • 日本語
  • हिन्दी
  • বাংলা
  • தமிழ்
  • తెలుగు
  • मराठी
All lab calculators
  1. Home
  2. Lab calculators
  3. Protein

Free · no sign-in · runs in your browser

Protein calculator: MW, extinction coefficient, pI and A280

Paste a sequence for its molecular weight, ε280, isoelectric point, titration curve, GRAVY and stability indices, then turn an A280 reading into mg/mL and µM. Values match ExPASy ProtParam.

Start calculatingHow it’s calculated

Start herePick a calculation

  1. 1Sequence parametersMW, ε280, Abs 0.1 %, pI, charge at pH 7, GRAVY, instability and aliphatic index, composition and titration curve.
  2. 2A280 concentrationBeer–Lambert concentration in mg/mL and µM from absorbance at 280 nm.
  3. 3mg/mL ↔ µMConvert between mass and molar protein concentration with the molecular weight.
All calculators1Sequence parameters2A280 concentration3mg/mL ↔ µMΣMethod?FAQ
1

ProtParam

Protein MW, extinction coefficient and pI

Paste a protein sequence (one-letter code) for its molecular weight, ε280, isoelectric point, charge, GRAVY and stability indices, calculated as ExPASy ProtParam does.

1Enter your values

FASTA header, spaces, numbers and a stop (*) are ignored. Default: human ubiquitin.

2Your result

Molecular weight

8,564.736Da

8.5647 kDa · 76 residues · average isotopic masses

ε280, Cys reduced1,490M⁻¹cm⁻¹ · Abs 0.1 % = 0.174
ε280, all cystines1,490M⁻¹cm⁻¹ · Abs 0.1 % = 0.174
Isoelectric point6.56net charge at pH 7: -0.40
GRAVY-0.489hydrophilic overall
Instability index36.06stable (< 40)
Aliphatic index100.0011 Asp+Glu · 11 Arg+Lys
Plot

Net charge vs pH

02.557.51012.5-10010pHnet chargepI 6.56
Show the calculation
  1. Sum of free amino acid masses, minus one water per peptide bond:MW = 9,915.8832 − (76 − 1) × 18.0153 = 8,564.7357 Da
  2. Extinction coefficient (Pace 1995):ε = 0×5500 (Trp) + 1×1490 (Tyr) + 0×125 (cystines) = 1,490
  3. Abs 0.1 % (a 1 mg/mL solution, 1 cm):1,490 ÷ 8,564.736 = 0.174
  4. pI: bisection for the pH where the Henderson–Hasselbalch charges sum to zero:charge(6.56) = 0.0000
  5. Instability index (Guruprasad 1990):II = 10 ÷ 76 × Σ DIWV(xᵢ, xᵢ₊₁) = 36.06
2

Spectrophotometry

Protein concentration from A280

Beer–Lambert concentration from absorbance at 280 nm, the extinction coefficient and molecular weight.

1Enter your values

M⁻¹cm⁻¹
cm
×

Blank the instrument against the same buffer.

2Your result

←Enter A280, ε and the molecular weight (or calculate them from the sequence above).Results appear here as you type.
3

Units

Protein mg/mL to µM (and back)

Convert between mass and molar protein concentration. Default: bovine serum albumin, 66.5 kDa.

1Enter your values

Direction
kDa

2Your result

Molar concentration

15.04µM

15.04 µM

Show the calculation
  1. Divide the mass concentration (g/L) by the molecular weight (g/mol):1 g/L ÷ 66,500 g/mol = 1.504 × 10⁻⁵ M

How it's calculated

The maths behind every result

Each equation below is exactly what the calculator runs. Open “Show the calculation” under any result to see it with your own numbers.

Molecular weight

The average molecular weight is the sum of the free amino acids’ average isotopic masses, minus one water for each peptide bond formed:

MW=∑i=1Nmaai−(N−1)×18.0153[g/mol=Da]MW = \sum_{i=1}^{N} m_{aa_i} - (N - 1) \times 18.0153 \quad [\text{g/mol} = \text{Da}]MW=i=1∑N​maai​​−(N−1)×18.0153[g/mol=Da]

It describes the unmodified polypeptide: add the mass of any tag, signal-peptide cleavage, disulfides (−2.016 Da each) or post-translational modification yourself.

Extinction coefficient at 280 nm

At 280 nm a folded protein absorbs through its tryptophans, tyrosines and disulfide-bonded cystines. Pace et al. (1995) fitted average molar absorptivities for each:

ε280=5500 nTrp+1490 nTyr+125 ncystine[M−1 cm−1]\varepsilon_{280} = 5500\,n_{\mathrm{Trp}} + 1490\,n_{\mathrm{Tyr}} + 125\,n_{\text{cystine}} \quad [\text{M}^{-1}\,\text{cm}^{-1}]ε280​=5500nTrp​+1490nTyr​+125ncystine​[M−1cm−1]

Two values are given: all cysteines reduced (ncystine=0n_{\text{cystine}} = 0ncystine​=0) and every pair forming a disulfide (ncystine=⌊nCys/2⌋n_{\text{cystine}} = \lfloor n_{\mathrm{Cys}}/2 \rfloorncystine​=⌊nCys​/2⌋). The absorbance of a 1 mg/mL solution, often written Abs 0.1 %, is ε280/MW\varepsilon_{280}/MWε280​/MW. The estimate is reliable for proteins that contain tryptophan and much less so for proteins without it.

References. Pace CN, Vajdos F, Fee L, Grimsley G, Gray T. How to measure and predict the molar absorption coefficient of a protein. Protein Sci. 1995;4:2411–2423.

Net charge and isoelectric point

Each ionisable group carries a fractional charge given by the Henderson–Hasselbalch equation. Summing them gives the net charge at any pH:

Z(pH)=∑basicnj1+10 pH−pKj  −  ∑acidicnk1+10 pKk−pHZ(\text{pH}) = \sum_{\text{basic}} \frac{n_j}{1 + 10^{\,\text{pH} - pK_j}} \;-\; \sum_{\text{acidic}} \frac{n_k}{1 + 10^{\,pK_k - \text{pH}}}Z(pH)=basic∑​1+10pH−pKj​nj​​−acidic∑​1+10pKk​−pHnk​​

The isoelectric point is the pH where Z=0Z = 0Z=0, found by bisection between pH 0 and 14 to 10⁻⁵. The pK values are Bjellqvist’s, as used by ExPASy and Biopython:

  • Basic: N-terminus 7.5, K 10, R 12, H 5.98
  • Acidic: C-terminus 3.55, D 4.05, E 4.45, C 9, Y 10
  • N-terminus by first residue: A 7.59, M 7, S 6.93, P 8.36, T 6.82, V 7.44, E 7.7; C-terminus by last residue: D 4.55, E 4.75

The prediction ignores folding, buried residues, modifications and buffer, so a measured pI can differ by a few tenths.

References. Bjellqvist B et al. The focusing positions of polypeptides in immobilized pH gradients can be predicted from their amino acid sequences. Electrophoresis 1993;14:1023–1031.

GRAVY, instability and aliphatic index

Grand average of hydropathy
GRAVY=1N∑i=1NhKD(aai)\text{GRAVY} = \frac{1}{N}\sum_{i=1}^{N} h_{KD}(aa_i)GRAVY=N1​i=1∑N​hKD​(aai​)
Instability index
II=10N∑i=1N−1DIWV(aai,aai+1)II = \frac{10}{N}\sum_{i=1}^{N-1} \text{DIWV}(aa_i, aa_{i+1})II=N10​i=1∑N−1​DIWV(aai​,aai+1​)
Aliphatic index
AI=100 (xAla+2.9 xVal+3.9 (xIle+xLeu))AI = 100\,\left(x_{\mathrm{Ala}} + 2.9\,x_{\mathrm{Val}} + 3.9\,(x_{\mathrm{Ile}} + x_{\mathrm{Leu}})\right)AI=100(xAla​+2.9xVal​+3.9(xIle​+xLeu​))
hKDh_{KD}hKD​
Kyte–Doolittle hydropathy of each residue (Ile 4.5 … Arg −4.5)
DIWV\text{DIWV}DIWV
dipeptide instability weight for each ordered pair of neighbours (Guruprasad 1990); II below 40 predicts a stable protein
xxx
mole fraction of the residue in the sequence

These are statistical predictors from sequence alone. They are useful for comparing constructs, not as a substitute for measuring stability or solubility.

References. Kyte J, Doolittle RF. J Mol Biol 1982;157:105–132. · Guruprasad K, Reddy BVB, Pandit MW. Protein Eng 1990;4:155–161. · Ikai A. J Biochem 1980;88:1895–1898. · Gasteiger E et al. Protein identification and analysis tools on the ExPASy server. In: The Proteomics Protocols Handbook, Humana Press, 2005.

Concentration from A280

The Beer–Lambert law relates absorbance to concentration through the extinction coefficient and path length:

A=ε c l    ⇒    c [M]=A280×Dε×l,c [mg/mL]=c [M]×MWA = \varepsilon\, c\, l \;\;\Rightarrow\;\; c\,[\text{M}] = \frac{A_{280} \times D}{\varepsilon \times l}, \qquad c\,[\text{mg/mL}] = c\,[\text{M}] \times MWA=εcl⇒c[M]=ε×lA280​×D​,c[mg/mL]=c[M]×MW

Blank against the same buffer, keep readings between about 0.1 and 1.5, and remember that nucleic acid contamination raises A280 (check A260/A280; pure protein is about 0.57).

FAQ

Protein calculator: common questions

How do I calculate protein concentration from A280?

Use the Beer–Lambert law: c (mol/L) = A280 × dilution / (ε × path length in cm), where ε is the molar extinction coefficient in M⁻¹ cm⁻¹. Multiply by the molecular weight to get mg/mL. For example GFP (ε = 21,890 M⁻¹ cm⁻¹, 26,886 g/mol) at A280 = 0.5 is 22.8 µM, or 0.614 mg/mL.

How is a protein extinction coefficient calculated from its sequence?

With the Pace et al. (1995) method used by ExPASy ProtParam: ε280 = 5500 × (number of Trp) + 1490 × (number of Tyr) + 125 × (number of cystines). Report both values: one assuming every cysteine is reduced and one assuming every pair forms a disulfide.

How is the isoelectric point (pI) calculated?

The net charge is summed over every ionisable group with the Henderson–Hasselbalch equation, using the Bjellqvist pK values that ExPASy uses (N-terminus 7.5, Lys 10.0, Arg 12.0, His 5.98, C-terminus 3.55, Asp 4.05, Glu 4.45, Cys 9.0, Tyr 10.0, with residue-specific terminal values). The pI is the pH where the net charge is zero, found by bisection.

What does the instability index mean?

Guruprasad et al. (1990) found that some dipeptides are more common in proteins with short half-lives. The index sums a weight for every adjacent pair of residues, scaled by 10 / length. A value below 40 predicts a stable protein in a test tube; above 40, possibly unstable. It is a statistical estimate, not a measurement.

What is GRAVY?

The grand average of hydropathy: the mean Kyte–Doolittle hydropathy value over every residue. Positive values indicate an overall hydrophobic protein (typical of membrane proteins), negative values a hydrophilic one.

More calculators

Other free lab calculators

All lab calculators

DNA

DNA calculator

DNA and RNA concentration from A260, ng/µL to nM molarity, copy number, ligation insert amounts and oligo molecular weight, with the formula for every result.

Open

PCR

PCR calculator

PCR master mix volumes for any number of reactions, primer melting temperature (nearest-neighbour, salt-corrected) and annealing temperature, and a cycling program from amplicon length.

Open

Dilutions

Dilution calculator

C1V1 = C2V2 solved for any value, serial dilution series with exact transfer volumes, standard curves from one stock, and molarity: grams to weigh for a solution.

Open

LabTools

Keep the calculation with the study

LabTools is a free research app for desktop, web and iPhone: studies, experiments, protocols, notebooks, statistics and publication plots in one place, shared with your lab.

Download freeSee features

LabTools

The research infrastructure: plot to figure to manuscript in one place. Free to start, with every feature on every plan.

Product

  • Features
  • Technology
  • Demo & Tutorials
  • Examples
  • Plans
  • Download

Support

  • Contact Support
  • Help Center

Filliaux Industries

  • filliaux.com
  • Data Analysis

Stay updated

Research tips, product updates, and release notes. No spam.

Language

  • English
  • 简体中文
  • Español
  • Français
  • Deutsch
  • Português (Brasil)
  • 日本語
  • हिन्दी
  • বাংলা
  • தமிழ்
  • తెలుగు
  • मराठी
© 2026 Filliaux Industries · LabToolsPrivacyTermsCookiesLinkedIn